Description
- The system plug board in the ND-Satellite, with connections for terminals, telefix and external communication.
- This is the actual template used in production.
- Print: A ECO: B
- PCB size 366 x 333 mm, 2 layers
- Release date xx. xxx. xxxx
Chipset
LEDs
Straps
Switches
- Baudrate for the ND-100 Console terminal and the Telefix modem
0 = switch on, 1 = switch off (or open)
Baud | | Terminal | | Modem |
rate | 1-A | 2-B | 3-C | 4-D | 5-A | 6-B | 7-C | 8-D |
50 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
75 | 1 | 0 | 0 | 0 | 1 | 0 | 0 | 0 |
110 | 0 | 1 | 0 | 0 | 0 | 1 | 0 | 0 |
134.5 | 1 | 1 | 0 | 0 | 1 | 1 | 0 | 0 |
150 | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 0 |
300 | 1 | 0 | 1 | 0 | 1 | 0 | 1 | 0 |
600 | 0 | 1 | 1 | 0 | 0 | 1 | 1 | 0 |
1200 | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 0 |
1800 | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 1 |
2000 | 1 | 0 | 0 | 1 | 1 | 0 | 0 | 1 |
2400 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 1 |
3600 | 1 | 1 | 0 | 1 | 1 | 1 | 0 | 1 |
4800 | 0 | 0 | 1 | 1 | 0 | 0 | 1 | 1 |
7200 | 1 | 0 | 1 | 1 | 1 | 0 | 1 | 1 |
9600 | 0 | 1 | 1 | 1 | 0 | 1 | 1 | 1 |
19200 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Connectors
- Telefix - Modem
- Console - The ND-100 system console
- Terminal 1
- Terminal 2
- HDLC-Link
- HDLC-Sync
- (A) System bus
- (B) System bus
|
Component side, PCB version A
Solder side, PCB version A
|